Category: Properties Of Steam And Steam Generators
-
Economiser
Economiser is a type of heat exchanger which exchanges some parts of the waste heat of flue gas to the feed water. It is installed between exit of the furnace and entry into the chimney. Generally, economiser is placed after feed pump to avoid the problem of priming in feed pump. If economiser is installed…
-
BOILER ACCESSORIES
The devices used in boiler to increase its efficiency and quality of steam are known as accessories. The names of some important accessories are as follows:
-
Manhole
This is opening in the boiler. It is used for cleaning and inspection purpose. Through this hole operator enters inside the boiler in idle condition.
-
Fusible Plug
The function of fusible plug is to extinguish the fire in the fire box, when water level in the boiler comes down the limit. It prevents from blasting the boiler, melting the tube, and overheating the fire box crown plate. The constructional details of fusible plug are shown in Figure 4.23. It is located in water space…
-
Blow-off Cock
The function of blow-off cock is to blow down the sediments collected at the bottom of the drum or to empty the boiler or to lower down the water level in the drum. The blow-off cock is fitted at lowest portion of the boiler. The casing is provided with two flanges—one is connected to the…
-
Steam Stop Valve
The function of steam stop valve is to stop or allow the flow of steam from boiler to steam pipe or from steam pipe to supply. The opening of the valve is controlled by a hand wheel. The constructional details of steam stop valve are very simple which is shown in Figure 4.21. Figure 4.21 Steam Stop…
-
Feed Check Valve
The function of feed check valve is to allow the flow of water under pressure from feed pump to boiler and to prevent the backflow of water in case of failure of the feed pump. The constructional details are shown in Figure 4.20. The valve rises under pressure and water is allowed to flow inside the drum.…
-
4.8.3 Water Level Indicator
The function of the water level indicator is to show the water level inside the boiler drum. Totally two water level indicators are provided on the boiler drum. The constructional details are shown in Figure 4.18. One end of the glass tubes is connected to steam space and other end to water space through a hollow pipe of…
-
High Steam Low Water Safety Valve
Following are the functions of high steam and low water safety valve: The constructional details of the high pressure low water safety valve are shown in Figure 4.17. The arrangement for the outer valve is similar to that of lever loaded valve. The balance or counter weight can be fixed at any position along the arm by…
-
Lever Safety Valve
Lever safety valve works on the principle of second system of lever as shown in Figure 4.16. In this valve, there is a lever which can rotate about fulcrum but its movement is limited by a guide. When moment about fulcrum due to steam pressure exceeds the moment about fulcrum due to weight applied on the lever,…