Distribution of Load

Distribution of load for two conditions are given below:

  1. In the case of stairs with open-well where spans partly crossing at right angles occur, the load on areas common to any two such spans may be taken as one-half in each direction (Fig. 21.16). C21F016.pngFigure 21.16 Distribution of loads on stairs (Source: IS: 456–2000)
  2. Where flights or landings are embedded into walls for a length not less than 110 mm and are designed to span in the direction of the flight a 150 mm strip may be deducted from the loaded area and the effective breadth of the section increased to 75 mm for the purpose of design (Fig. 21.17). C21F017.pngFigure 21.17 Loading on stairs built into walls (Source: IS: 456–2000)